TM-9-2920-257-30-P

GENERATOR, ALTERNATING CURRENT, 200 AMPERES

TECHNICAL MANUAL; DIRECT SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS

MAY 1987

  TM-9-2920-257-30-P - Page 63 of 111

TM 9-2920-257-30&P
NOTE
Scribe cover plate and front housing before removing cover plate
(10.) Remove six screws (16) and cover (17) from front housing (18).
NOTE
There are two connector assembly configurations, both procedures for removal
and repair are the same.
(11.)
Remove connector assembly from front of housing.
Tag all leads.
See page 3-6 steps 3 and 4 for
procedure to remove connector assembly.
NOTE
Mark front housing and stator shell to insure proper alignment when generator is
reassembled
(12.)
Remove nine flanged locknuts (10), front housing (18), with core and rotor attached from studs on stator
housing (12).
Discard locknuts.
NOTE
Light taps with a soft-faced mallet will help in the separation of the parts.
Change 1
3-33