MWO-5-2350-262-35-4

ARMORED COMBAT EARTHMOVER (ACE), M9

MODIFICATION WORK ORDER

  MWO-5-2350-262-35-4 - Page 78 of 207

MWO 5--2350--262--35--4
3--49
SECTION II INSTALLATION OF HDC PRIMARY MANIFOLD ASSEMBLY,
MANUAL SHUT–OFF VALVE V23, AND LEFT MAIN MANIFOLD PRESSURE
TRANSDUCER T7 -- CONTINUED
3--8
CONNECTION OF OTHER HYDRAULIC COMPONENTS TO HDC PRIMARY
MANIFOLD ASSEMBLY AND DCV BANK -- CONTINUED
CAUTION
If a hydraulic test stand or other hydraulic facilities are not available to adjust the pressure
relief valve setting, the adjustment should be made when the pressure relief valve is
installed.
NOTE
Step p below applies to Figure 3--31.
p.
Using hydraulic test stand, or other available hydraulic facilities, set pressure relief valve to 4300 +/-- 50
psi (29647.46 +/-- 344.7379 kilopascal), at 5 +/-- 2 GPM (18927.06 +/-- 7570.824 CPM).
Figure 3--31. Interconnection of Components After Modification


Back to Top