TM 9-2320-273-34
(3)
Before condemning a rotor for an open coil, check the solder joints at the slipring leads, as
a poor connection at either of these leads will cause the same test result as an open coil, If the proper
resistance is not obtained after resoldering these connections, replace the rotor.
g. Stator Test.
Replace any stator that appears overheated (discolored) or that has charred insulation,
regardless of how they test. Perform continuity and ground tests as follows:
NOTE
Do not test the stator while it is connected
to the heatsinks. Remove the stator from
the alternator before testing.
(1)
Check for continuity by connecting a 115-vat test light to each of the lead combinations in
figure 5-22. If the lamp fails to light in any combination, replace the stator.
Figure 5-22. Stator Continuity Test.
TA 074020
(2)
Check for a ground by connecting the 115-vac test light as shown in figure 5-23. If the lamp
lights, replace the stator.
TA 074021
Figure 5-23. Stator Ground Test.