h. Transformer-Rectifier Test.
.
The transformer-rectifier is checked as follows:
(1)
infinity reading
replaced.
Use an ohmmeter (fig. 5-24) to check for continuity of the transformer windings.
is indicated between any two ac terminals, that winding is open and the unit must
If an
be
TA 074022
Figure 5-24. Transformer-Rectifier Open Test.
(2)
Use an ohmmeter (fig. 5-25) to check for grounds between the five terminals and the hous-
ing. Any reading other than infinity indicates an internal ground and the unit must be replaced.
TA 074023
Figure 5-25. Transformer-Rectifier Ground Test.