TM9-2320-273-34
5-7. Bench Testing.
a.
Test Setup.
Because of the internal regulator used on this alternator, the test stand hookup
consists only of connecting the positive and negative output leads.
b. Preparation.
Before beginning the test, and after making the above connections, momentarily
flash the field by connecting a jumper between the diode trio terminal and the alternator positive output
terminal (fig. 5-36). This will restore the residual magnetism which may have been weakened by handling
or repair procedures.
TA 074031
Figure 5-36. Restoring Residual Magnetism.
c. Testing the Alternator (72- Volt dc Output).
Test the alternator as follows:
(1) Set the test stand speed so that the alternator is running at
580-620
rpm.
(2) Adjust the regulator output to 14 volts dc.
(3) Vary the load on the alternator between 1 ampere and 85 amperes and check that the
output matches the load.
d. Testing the Alternator with Transformer-Rectifier (24- Volt dc Output).
Check the 24-volt
charging output as follows:
(1) Set the test stand speed so that the alternator is running at 580-620 rpm.
(2) Adjust the regulator output to 28 volts dc.
(3) Vary the load between 1 ampere and 15 amperes and check that the output matches
the load.
5-29