TM9-2320-273-34
TA 074033
Figure 5-38. Motor and Switch Electrical Circuit.
5-9. Special Tools.
Special tools required for adjusting the solenoid switch installation and for the timing
test are shown in figure 5-39.
Figure 5-39. Starting Motor Special Tools.
5-10. Disassembly.
a. Solenoid Switch Removal.
Remove the solenoid switch as follows:
TA 074034
To remove the jumper strap retaining nut
at the No. 3 switch stud and at the field
ring, it is necessary to heat the stud to
approximately 300°F (149°C), Failure
to do this may result in breakage of the
plastic end base that retains the stud.
5-31
CAUTION