TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 743 of 1390

TM 9-2320-328-13&P-2
0216-1
DRAFT
0216
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL PRESSURE GOVERNOR CONTROL REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Loosen screw (1) and disconnect pressure governor control connector (2) from pressure governor control (3).
NOTE
Note orientation of pressure governor control prior to removal to ensure proper installation.
2.
Remove four screws (4), washers (5), pressure governor control (3), and mounting bezel (6) from pump
operator’s panel (7).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1237
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Lockwasher (2)
References
WP 0391, Fig. 34
Equipment Conditions
Pump operator’s panel opened (WP 0207)


Back to Top