FIELD LEVEL MAINTENANCE
STRIPLIGHT REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Remove cable ties as required.
All striplights except pump operator’s panel are removed the same way.
Top stowage
compartment striplight shown.
Pump operator’s panel striplights have connectors.
1.
Disconnect connector (1) from connector (2).
NOTE
Striplight and cover are removed as an assembly.
2.
Remove two screws (3), cover (4), and striplight (5) from stowage compartment box (6).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1520
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
Lockwasher (4)
References
WP 0391, Fig. 62
Equipment Conditions
Batteries disconnected (TM 9-2320-325-14&P)
Compartment door opened (WP 0008)