TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 729 of 1390

TM 9-2320-328-13&P-2
0211-3
DRAFT
0211
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Visually verify that foam tank is filled to within two inches from the top of the foam tank
(WP 0022).
The magnet used to calibrate foam level gauge is taken from behind passenger side
SCBA seat headrest.
NOTE
The term “swipe” means to move the magnet up to and then away from CAL. located just
left of the LED display on the foam level gauge.
The magnet must be moved at least 1 in.
(2.54 cm) away when “swiping” the sensor.
The sensor that is activated behind CAL. is activated by the north pole of the magnet.
The
sensor will not respond to the south pole.
Polarity of magnet can be determined by rolling
magnet over a non magnetic surface and observing the side of the magnet that faces
north.
Once the calibration procedure starts, there is a six second time out.
Do not wait more
than six seconds to move from Step (4) to Step (5).
HWT3449
HWT3450


Back to Top