TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 761 of 1390

TM 9-2320-328-13&P-2
0221-1
DRAFT
0221
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL TOGGLE SWITCH (THREE-POSITION) REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Remove cable ties as required.
1.
Remove three screws (1), lockwashers (2), wire 2316 (3), wire 2314 (4), and wire 2315 (5) from three-position
toggle switch (6).
Discard lockwashers.
NOTE
Note position of three-position toggle switch prior to removal to ensure proper installation.
2.
Remove nut (7), washer (8), and three-position toggle switch (6) from pump operator’s panel (9).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT0011
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing (WP 0400, Item 10)
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
Materials/Parts (continued)
Lockwasher (3)
References
WP 0391, Fig. 34
Equipment Conditions
Pump operator’s panel opened (WP 0207)


Back to Top