TM 9-2330-227-14&P
INSIDE DOMELIGHT, 24-VOLT - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REPAIR - CONTINUED
7.
Body (14)
Door assembly (12)
Lift off, and turn upside down.
Wire (15) will still be connected
between connector (10) and rotary
switch (16). Rubber seal may
remain in door assembly.
8.
Wire (15)
Using long round-nose pliers, pull out.
NOT E
When removing wires from rotary switch , tag wires and terminals so wires can be
connected correctly (page 4-4).
9.
Wire (15)
Screw (17)
Using 3/16-inch flat-tip screwdriver,
unscrew and take off.
10.
Terminal (18)
11.
Wire (19)
Wire (15)
Screw (20)
Lift off.
Using 3/16-inch flat-tip screwdriver,
loosen.
12.
Terminal (21)
Wire (19)
Using long round-nose pliers, pull off.
13.
Wire (22)
Screw (23)
Using 3/16-inch flat-tip screwdriver,
loosen.
14.
Terminal (24)
Wire (22)
Using long round-nose pliers, pull off.
4-63