TRANSDUCER
INVERSION
VALVE
AIR LINE
2226
Figure 7.
Inversion Valve and Air Line 2226.
8.
Connect TK pressure transducer (blue stripe) to air hose 2226.
9.
Perform ICE Offset Test 50.
CONDITION/INDICATION
Does test equipment pass offset test?
DECISION
Yes - Go to (Step 8 - Does air bag control valve supply 125 ± 5 psi (861 ± 34 kPa) to air bag?).
No - Test equipment failed offset. Contact your Supervisor.
STEP 8
Does air bag control valve supply 125 ± 5 psi (861 ± 34 kPa) to air bag?
1.
Start engine. Refer to vehicle Operator's manual (WP
0190).
2.
Perform ICE Test 50.
3.
Push in trailer charge valve in vehicle. Refer to vehicle Operator's manual (WP
0190).
4.
Have assistant raise air bag control lever to up position. Refer to TM 9-2330-342-10 (WP
0190).
TM 9-2330-342-23&P
0028
0028-8