TRANSDUCER
AIR
CHAMBER
AIR LINE 2078
CHAMBER
ROD
FLATRACK
LOCKING
MECHANISM
AIR
CHAMBER
AIR LINE
2081
CHAMBER
ROD
Figure 1.
Flatrack Locking Valve and Air Lines 2078 and 2081.
CONDITION/INDICATION
Are air lines 2078 and 2081, and fittings free of crimps?
DECISION
Not Crimped - Go to (Step 2 - Does flatrack locking valve exhaust air when pulled out?).
Crimped - Repair or replace hose(s) and fitting(s) (WP
0067). Go to (Step 5 - Does flatrack locking mechanism
latch(es) lock?) to verify problem is solved.
STEP 2
Does flatrack locking valve exhaust air when pulled out?
WARNING
Be sure to wear the proper eye protection when working on or around pressurized air systems
if not injury or death could result.
1.
Pull out flatrack locking valve and listen for air to exhaust. Refer to TM 9-2330-342-10
(WP
0190).
TM 9-2330-342-23&P
0029
0029-2