6.
Remove safety valve and T-fitting from air bag (WP
0082).
7.
Connect TK pressure transducer (blue stripe) to T-fitting.
8.
Connect air line 2224 to adapter on T-fitting.
TRANSDUCER
SAFETY
VALVE
AIR LINE
2224
AIR
BAG
Figure 11.
Air Bag and Air Line 2224.
9.
Perform ICE Offset Test 50.
CONDITION/INDICATION
Does test equipment pass offset test?
DECISION
Yes - Go to (Step 12 - Does safety valve release at 53-56 psi (365-386 kPa)?).
No - Test equipment failed offset. Contact your Supervisor.
STEP 12
Does safety valve release at 53-56 psi (365-386 kPa)?
1.
Perform ICE Test 50.
2.
Have assistant raise air bag control lever up. Refer to TM 9-2330-342-10 (WP
0190).
3.
Observe meter reading.
TM 9-2330-342-23&P
0028
0028-12