TM 9-2350-238-20-1
2-101. MAINTENANCE OF BULKHEAD DISCONNECT TO CIRCUIT BREAKER
BRANCHED WIRING HARNESS.
This task covers:
a.
Removal
d.
Reassembly
b.
Disassembly
e.
Installation
c.
Inspection/Repair
INITIAL SETUP
Materials/Parts
Electrical wire (figure D-2, appx D)
Gasket
Nonmetallic rod (figure D-24, appx D)
References
TM 9-2350-238-24P-1
Equipment Conditions
2-840 Batteries disconnected and removed
2-384 Hull access cover removed
Genera/ Safety Instructions
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
Failure to remove or disconnect batteries before removing or installing any electrical
wiring harness or lead may result in injury or damaged equipment.
1
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. Remove only the hardware which secures the wiring harness or lead
which is being removed.
2-682