TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 765 of 1364

TM 9-2350-238-20-1
1
2
3
4
5
6
7
8
9
10
11
Install slave receptacle connector (1) and four screws (2) in hull.
Install slave receptacle and ground electrical lead (3) in hull.
Untag and connect cable terminal (4) of slave receptacle and ground electrical lead to slave
receptacle connector (1).
Untag and connect cable terminal (5) of slave receptacle and ground electrical lead to hull.
Install voltage regulator to bulkhead disconnect, slave receptacle, and accessories panel special
cable assembly (6) in hull.
Untag and connect four shell connectors (7) to circuit breakers.
Connect cable terminal (8) of voltage regulator to bulkhead disconnect, slave receptacle, and
accessories panel special cable assembly to slave receptacle connector (1).
Connect plug connector (9) to
Untag and connect receptacle
(12) .
Untag and connect receptacle
(15).
voltage regulator.
connector (10), and install four washers (11) and four screws
connector (13), and install four washers (14) and four screws
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-122. MAINTENANCE OF AIR CLEANER BLOWER RELAY TO BULKHEAD
DISCONNECT BRANCHED WIRING HARNESS.
This task covers:
a.
Removal
d.
Reassembly
b.
Disassembly
e. Installation
c. Inspection/Repair
INITIAL SETUP
Materials/Parts
Electrical wire (figure D-2, appx D)
Nonmetallic rod (figure D-24, appx D)
References
TM 9-2350-238-24P-1
Equipment Conditions
2-640 Batteries disconnected
2-952 Driver’s seat removed
General Safety Instructions
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
2-739


Back to Top