MAY 1994

  TM-9-2350-238-20-1 - Page 757 of 1364

TM 9-2350-238-20-1
4
Disconnect shell connector (4) from
transmission oil thermostatic switch.
5
Remove aeration detector branched wiring
harness (5) from powerplant.
1
Inspect for broken, damaged, or missing
parts.
2
If damaged or missing, replace marker
bands. Etch or stamp lead number on
new band.
3
For repair of shell connectors, refer to
general maintenance, page 2-371.
1
Install aeration detector lead and diode
assembly (3) in powerplant.
2
Connect shell connector (6) to line
connection.
3
Install aeration detector branched wiring
harness (5) to powerplant.
4
Connect shell connector (4) to
transmission oil thermostatic switch.
6
7
4
5
5
6
7
Disconnect shell connector (6) from line
connection.
Remove aeration detector lead and diode
assembly (3) from powerplant.
Electrical wire is a manufactured item,
refer to appendix D.
Repair is by replacement of authorized
parts (TM 9-2350-238-24 P-1).
Connect shell connector (2) to aeration
detector lead and diode assembly (3).
Connect shell connector (1) to horn relay.
Wiring harnesses and leads are secured to
the powerplant with loop clamps, straps,
ground screws, etc. During installation,
make sure the wiring harness or lead is
secure and all hardware is tight.
2-119. MAINTENANCE OF LOW COOLANT WARNING LIGHT TO BULKHEAD
DISCONNECT BRANCHED WIRING HARNESS.
This task covers:
a.
Removal
d.
Reassembly
b.
Disassembly
e. Installation
c.
Inspection/Repair
INITIAL SETUP
Materials/Parts
Electrical wire
References
General Safety Instructions
(figure D-2, appx D)
I
TM 9-2350 -238-24P-1
Failure to remove or disconnect
batteries before removing or installing
Equipment Conditions
any electrical wiring harness or lead
2-640 Batteries disconnected
may result in injury or damaged
2-952 Driver’s seat removed
equipment.
2-731