TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 755 of 1364

TM 9-2350-238-20-1
1
Inspect for broken, damaged, or missing
parts.
2
If damaged or missing, replace marker
bands. Etch or stamp lead number on
new band.
3
For repair of shell connectors and cable
terminals, refer to page 2-371.
1
2
3
4
5
6
7
Install warning light low coolant detector to
bulkhead disconnect branched wiring
harness (1) on powerplant.
Untag and connect cable terminal (2) to
ground.
Untag and connect three cable terminals
(3) to aeration detector.
Install aeration detector cover (4) and two
screws (5).
Untag and connect shell connector (6) to
diode assembly and transmission
temperature warning switch.
Untag and connect two shell connectors
(7) to line disconnects to warning light.
Wiring harnesses and leads are secured
to the engine with loop clamps, straps,
ground screws, etc. During installation,
make sure the wiring harness or lead is
secure and all hardware is tight.
4
Electrical wire is a manufactured item,
refer to appendix D.
5
Repair is by replacement of authorized
parts (TM 9-2350-238-24P-1).
2-729