TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 756 of 1364

TM
2-1
9-2350-238-20-1
18. MAINTENANCE OF AERATION DETECTOR BRANCHED WIRING HARNESS.
This task covers:
a.
Removal
b.
Inspection/Repair
c. Installation
INITIAL SETUP
Matetials/Parts
Electrical wire (figure D-2, appx D)
References
TM 9-2350-238-24P-1
Equipment Conditions
2-640 Batteries disconnected
2-384 Powerplant removed
General Safety Instructions
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
2
may result in injury or damaged
equipment.
3
1
Wiring harnesses and leads are secured to
the powerplant with loop clamps, straps,
ground screws, etc. Remove only the
hardware which secures the wiring
harness or lead being removed.
Tag and disconnect shell connector (1)
from horn relay.
Tag and disconnect shell connector (2)
from aeration detector lead and diode
assembly (3).
2-730


Back to Top