TM 9-2350-260-20-1-2
PRIMER PUMP REPLACEMENT (Sheet 4 of 4)
5.
Using 9/16 inch wrench, install inlet tube (E) and
heater tube (F) on tee (C).
6.
Using 9/16 inch wrench, install outlet tube (G) on
adapter (D).
7.
Apply silicone compound (Item 32, Appendix D) to
two electrical connectors (H).
8.
Connect two electrical connectors (H) located on
handle support bracket (J) by pushing together.
9.
Raise handle to up position.
Using 7/16 inch
wrench, install wire bracket (K) with bolt (L).
End of Task
TA148398