TM-9-2350-261-20-3

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 3 OF 4

  TM-9-2350-261-20-3 - Page 44 of 932

TM 9-2350-261-20-3
REPLACE POWER PLANT DOOR — Continued
0427 00
WARNING
Hanging loads, heavy parts, and overhead equipment can fall unexpectedly and kill or injure
you.
Stay clear of hanging loads, heavy parts, and overhead equipment. Use correct lifting devices.
Always have helper guide heavy parts and equipment.
1.
Connect a suitable lifting device and sling around power plant door. Hold door straight up until tension is gone. Have
helper assist.
2.
Remove four screws (1), washers (2), two brackets (3) and (4), plates (5), and power plant door (6) from hull.
3.
Remove two spacers (7) from ends of power plant door (6).
0427 00-2