3 Use black dipstick (5) to obtain a small sample of battery acid.
4 Place a few drops of acid onto measuring surface (3) through opening in cover plate.
5 Point instrument toward any light source (headlight) and look into eyepiece (6). The battery charge is at a point
on the left part of the scale where the dividing line between light and dark (shadow) crosses the scale.
NOTE
A little experience will enable you to quickly obtain the best contrast between light and
dark portions of the field of view. Tilt the instrument toward the light source until the
best results are obtained. If the edge of the shadow
surface was not sufficiently cleaned or dried.
is not sharp, the measuring
b. Removal
WARNING
• Battery gases can explode. Do not smoke or allow sparks or open flames near
batteries. Wear safety glasses or goggles when checking batteries. Failure to
follow this procedure could cause serious injury or death.
• When working on batteries, wear eye protection and remove all jewelry, dog tags,
and metal items to avoid electrical shock and bums.
CAUTION
When removing batteries, always disconnect ground leads first to prevent damage to
batteries.
8-77