TM 9-2350-311 -20-1
8-30 BILGE PUMP RELAY — CONTINUED
b. Installation
Ensure MASTER switch is OFF when working on bilge pump relay to avoid electrical
shock and burns.
1 Remove two nuts (2), two Iockwashers (3), two screws (6), four external-tooth Iockwashers (4), and two flat
washers (5). Secure starter relay (8). Discard Iockwashers and external-tooth Iockwashers.
2 Install bilge pump relay (7), two flat washers (5), four new external-tooth Iockwashers (4), two screws (5), two
new Iockwashers (3), and two nuts (2).
3 Connect electrical connector (1).
8-82
WARNING