TM 9-2350-311-20-1
a. Removal
WARNING
Ensure MASTER switch is OFF when working on bilge pump circuit breaker to avoid
electrical shock and bums.
1 Remove two screws (1) and two washers (2).
2 Remove three electrical leads (3) from circuit breaker (4).
3 Remove two screws (5), two flat washers (6), two Iockwashers (7), and two nuts (8). Discard Iockwashers.
4 Remove circuit breaker (4).
b. Installation
WARNING
Ensure MASTER switch is OFF when working on bilge pump circuit breaker to avoid
electrical shock and bums.
1 Install circuit breaker (4).
2 Install two new Iockwashers (7), two flat washers (6), two screws (5), and two nuts (8).
3 Install three electrical leads (3) on circuit breaker (4), two washers (2), and two screws (1).
8-85