TM 9-2350-311-20-1
8-31 STARTER RELAY BOX — CONTINUED
b. Installation
1
2
3
WARNING
Ensure MASTER switch is OFF when working on starter switch relay boxes to avoid
electrical shocks and bums.
Remove two nuts (2), two Iockwashers (3), two screws (6), four external-tooth Iockwashers (4), and two flat
washers (5). Secure bilge pump relay (8). Discard Iockwashers and external-tooth Iockwashers.
Install starter relay box or starter protection relay box (7), two new Iockwashers (3), four new external-tooth
Iockwashers (4), two flat washers (5), two screws (6), and two nuts (2).
Connect electrical connector (1).
8-32 BILGE PUMP CIRCUIT BREAKER
This task covers:
a. Removal
b. Installation
INITIAL SETUP
General mechanic’s tool kit (item 64, Appx H)
Lockwashers (2) (item 86, Appx G)
Tools
8-84