TM 9-2350-311 -20-1
6-36 AIR CLEANER BLOWER RELAY AND AIR CLEANER BLOWER MOTORS —
CONTINUED
a. Removal — Continued
2
3
4
5
6
7
8
9
Remove nut (2), ground lead end (3), and washer (4).
Remove two nuts (5), flat washer (6), and air cleaner blower relay (7).
Remove bracket (8), three mounts (9), ground lead (10), and washer (11).
Disconnect two electrical leads (12).
Turn four screws (13) counterclockwise to loosen four clamps (1 4).
Disconnect four hoses (15) from blower motors (16).
Loosen two screws (17) to loosen clamps (18).
Pull blower motors (16) out of two clamps (18).
8-92