TM 9–2350–311–20–2
6–26
6–9
ACCUMULATOR ASSEMBLY (MANUAL PUMP) — CONTINUED
c.
Installation
1
If removed, install loop clamp (5) with two cap screws (6).
2
Insert accumulator (3) into loop clamp (5) and secure with nut (4).
3
Connect hydraulic line to base of accumulator (3). Tighten hex nut (1) over clinch sleeve (2) to secure line.
4
Check hydraulic fluid level (para 6–2).
3
4
1
2
5
6