TM-9-2520-270-34

HYDROMECHANICAL CROSSDRIVE, TRANSMISSION HMPT 500 AND TRANSMISSlON CONTAINER ASSEMBLY

TECHNICAL MANUAL; DIRECT AND GENERAL SUPPORT MAINTENANCE

NOVEMBER 1984

  TM-9-2520-270-34 - Page 544 of 933

TM 9-2520-270-34
NOTE
Spur gear and bearing may have been removed.
Keep it with this housing.
3. REMOVE SPINDLE ASSEMBLY (1)
IF
a.
b.
c.
d.
INSTALLED.
Remove two screws (2), washers (3),
and sleeve spacers (4).
Rotate spindle cap (5) until it
partly covers screw hole (6).
Using screwdriver in screw holes (6),
pry up spindle cap (5).
Remove spindle assembly (1).
6. REMOVE RING (8).
a.
b.
Squeeze ring (8) with fingers until
hooks (9) release.
Spread open and remove ring (8).
Discard ring.
4. REMOVE AND DISCARD TWO
PREFORMED PACKINGS (7).
5. INSPECT METAL SEAL RING (8).
a. Inspect ring (8) for damage. See
page 2-5.
b. If ring (8) is damaged, go to step 6.
If not, go to step 7.
WARNING
Use care when removing
retaining ring. Retaining ring
can fly. Personnel can be
injured. Always wear goggles.
7. REMOVE RETAINING RING (10) AND
SHIM (11).
a. (H) Reach in through controller
opening (12) and pry up cross
shaft (13).
b. Using retaining-ring pliers, remove
retaining ring (10).
c. Remove shim (11).
GO TO NEXT PAGE
4-221


Back to Top