TM 9-2520-270-34
13.
14.
15.
a. Use pry slot (5) to loosen housing
assembly (4).
INSTALL TWO EYEBOLTS (1) IN
TWO THREADED HOLES (2).
ATTACH AND SECURE LIFTING
DEVICE (3) TO TWO EYEBOLTS (1).
LOOSEN HOUSING ASSEMBLY (4).
CAUTION
Cross shaft must slide free when removing
housing assembly. Failure to do so can
cause damage to equipment.
16. PARTIALLY RAISE HOUSING
ASSEMBLY (4) TO FREE COMPONENTS.
a.
b.
c.
(H) Feed hose assembly (6) through
hole (7), Repairer lift housing
assembly (4) evenly 1/4 inch at a
time. Do not allow cross shaft (8)
to stick in spur gear (9).
Inspect that spur gear cluster (10)
is not stuck to housing assembly (4).
If spur gear cluster (10) is stuck
to housing (4), remove it and place
in positive clutch (11).
GO TO NEXT PAGE
4-223