NOTE
The steps that follow are a check on the assembly of stator components. If the stator turns
when you turn it to the right (clockwise) but does not move when you turn it to the left
(counterclockwise), the rollers and springs were properly installed in the stator group.
If the stator does not move when turned to the right (clockwise), the freewheel roller springs
and rollers have been incorrectly installed. Refer to Repair Converter Pump Components
(WP 0040).
13.Turn the stator (Figure 15, Item 15) to the right (clockwise). The stator will not turn to the left (counterclockwise).
14.Install the torque converter turbine assembly (Figure 15, Item 14) on the turbine shaft (Figure 15, Item 13).