REMOVAL
1.
Remove oil gauge rod (Figure 1, Item 1) from tube assembly (Figure 1, Item 8).
2.
Unscrew tube assembly (Figure 1, Item 8) from adaptor (Figure 1, Item 7) in left side of oil pan.
3.
Remove screw (Figure 1, Item 9), lockwasher (Figure 1, Item 6), nut (Figure 1, Item 5), clip
(Figure 1, Item 10), and tube assembly (Figure 1, Item 8) from bracket (Figure 1, Item 2) on flywheel
housing. If necessary, remove clip from tube assembly (Figure 1, Item 8). Discard lockwasher.
4.
Remove two screws (Figure 1, Item 4), two lockwashers (Figure 1, Item 3), and bracket (Figure 1, Item 2)
from left side of flywheel housing. Discard lockwashers.
1
2
5
6
4
3
7
8
9
10
3
MAINT_040
Figure 1.
Oil Level Gauge Rod Removal and Installation.
END OF TASK
TM 9-2815-205-24
0014
0014-2