INSTALLATION - Continued
4.
Install new gasket (Figure 5, Item 18), water outlet tee (Figure 5, Item 1), two flat washers (Figure 5, Item 9),
two new lockwashers (Figure 5, Item 8), and two screws (Figure 5, Item 7) on front of left cylinder head.
Torque screws to 30–35 lb-ft (41–47 N·m).
5.
Install bracket (Figure 5, Item 5), three flat washers (Figure 5, Item 2), three new lockwashers
(Figure 5, Item 3), one short screw (Figure 5, Item 6), and two long screws (Figure 5, Item 4) on water outlet
tee (Figure 5, Item 1) and cylinder head. Torque screws to 30–35 lb-ft (41–47 N·m).
6.
Install new gasket (Figure 5, Item 17), water outlet elbow (Figure 5, Item 16), two new lockwashers
(Figure 5, Item 14), two flat washers (Figure 5, Item 15), and two screws (Figure 5, Item 13) to front of right
cylinder head. Torque screws to 30–35 lb-ft (41–47 N·m).
7.
If removed, install plug (Figure 5, Item 12) in water outlet elbow (Figure 5, Item 16).
8.
Slide two hoses (Figure 5, Item 11) and four clamps (Figure 5, Item 10) onto crossover tube
(Figure 5, Item 19). Install crossover tube between water outlet elbow (Figure 5, Item 16) and water outlet
tee (Figure 5, Item 1). Slide two hoses and four clamps over connections and tighten clamps.
1
2
3
4
5
2
3
6
7
8
9
10
10
11
12
13
14
15
16
17
18
19
MAINT_147
Figure 5.
Thermostat Housing and Crossover Tube Installation.
END OF TASK
FOLLOW ON TASK
Install angle bracket and air pump assembly bracket (WP 0044).
END OF TASK
END OF WORK PACKAGE
TM 9-2815-205-24
0048
0048-6