CLEANING
NOTE
Remove all plugs from cylinder block except flush mounted dowel pins.
1.
Scrape all gasket material from cylinder block.
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury, illness, or death to
personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
2.
Clean inner and outer surfaces of cylinder block with cleaning solvent.
3.
Clean water, air, and oil passages with bore brush. Flush passages with cleaning solvent and blowout with
compressed air.
4.
Dry cylinder block with compressed air.
END OF TASK