TM 9-2815-210-34-2-2
FRAME 4
1.
2.
3.
4.
Check that rocker arm shaft (1) is not cracked or broken. If rocker arm
shaft is cracked or broken, throw it and rocker arm supports (2) away and
get new ones.
CAUTION
It is easy to damage
what you are doing.
you are experienced
person with you.
the equipment if you do not know
Do not try to do this task unless
at it, or you have an experienced
NOTE
Bearing surfaces of rocker arm shaft (1) are surfaces
next to oil holes in rocker arm shaft.
Check that rocker arm shaft (1) does not have worn bearing surfaces and that
rocker arm shaft is not scored.
If rocker arm shaft is scored or has worn bear-
ing surfaces, throw it and rocker arm supports (2) away and get new ones.
Check that locating dowel pin (3) is not cracked, chipped or loose. If it is
damaged or loose, throw away rocker arm shaft (1) and locker arm supports
(2) and get new ones.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame.
Keep a fire extinguisher nearby when sol-
vent is used.
Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and
damage to equipment.
Check that rocker arm shaft (1) has no small nicks, scratches or burrs. Fix
small nicks, scratches or burrs with a crocus cloth dipped in dry cleaning
solvent.
GO TO FRAME 5