5-77
TB 9-2320-280-35-15
NOTE
DAGR power cable positive lead insulation is ribbed.
33-24.
Attach shrink tubing (46) and terminal lugs (44) and (50) to PLGR power cable negative lead (49)
and DAGR power cable positive lead (47). (Refer to TM 9-2320-280-20 for terminal connector
repair.)
33-25.
Attach DAGR power cable positive lead (47) to 24V terminal board (52) located on cab enclosure
panel (43) with existing nut (45).
33-26.
Attach DAGR power cable negative lead (49) to ground strap (51) located on cab enclosure panel (43)
with existing nut (45).
33-27.
Coil excess positive and negative power leads, place beneath ground strap, and secure with tiedown
strap (48).
NOTE
Ensure all excess antenna cable is inside cab of vehicle.
33-28.
Coil excess antenna cable and store under integrated rack using tiedown strap as necessary.
(Refer to figure 5-90.)
33-29.
Install right-side tunnel insulation. (Refer to TM 9-2320-280-20.)
Figure 5-91.
44. TERMINAL LUG – 7728780 – QTY. 1
46. SHRINK TUBING – MS23053/4-302-0 – QTY. A/R
48. TIEDOWN STRAP – MS3367-1-0 – QTY. A/R
50. TERMINAL LUG – 7728777 – QTY. 1
43
44
45
48
45
49
46
50
51
52
46
47
~