TM 3-1040-268-20&P
2-8. DISCHARGERS - MAINTENANCE INSTRUCTIONS (CONT).
LOCATION
ITEM
ACTION
REMARKS
c. Electrical Receptacle Connector - Maintenance Instructions (Cont).
INSTALLATION (Cont).
1 Cover Plate (Cont),
a. Electrical Receptacle e.
connector (1) (Cont).
f.
g.
h.
i.
Cut three pieces of insulation sleeving 3/4-inch
long.
Slide new insulation sleevings on wires A, B,
and C.
Using remover, remove pins A, B, and C.
Insert wire leads into pins A, B, and C and solder See TB SIG 222.
(item 6, app D).
Slide insulation sleevings over soldered con-
nections and heatshrink.
CAUTION
Make sure that pins soldered to wires A and C are matched with holes A and C in electrical
receptacle connector or discharger will fire improper smoke pattern.
j. Using remover, insert pins A, B, and C into
electrical receptacle connector (1).
2-26