2-8. DISCHARGERS - MAINTENANCE INSTRUCTIONS (CONT).
LOCATION
ITEM
ACTION
REMARKS
c. Electrical Receptacle Connector - Maintenance Instructions (Cent).
REMOVAL (Cent).
2 Cover Plate (Cent).
Electrical Receptacle
b. Remove four self-locking nuts (9),
Connector (2) (Cent).
packings with retainers (10), and
screws (11 ).
c. Remove electrical receptacle con-
plate (1).
d. Discard items 2 and 10.
1 Cover Plate
Gasket (1)
a. Check material. If brittle or torn, scrape gasket
from mating surfaces.
b. Remove protective paper from adhesive on
cover plate side of gasket.
c. Install new gasket on cover plate (2).