d. Ground Wire - Maintenance Instructions
1 Body
2 Cover Plate
CAUTION
To avoid damage to discharger, do not put strain on wires.
a. Cover plate (1)
a. Remove six bolts (2) and six Iockwashers (3).
b. Remove cover plate from body (4).
c. Rotate 360° to unwind wires.
d. Prop against body.
b. Ground wire B
Remove ground screw (5) and disconnect termi-
nal (6).
Electrical receptacle
a.
connector (7)
b.
c.
Using remover, remove pin B.
Remove insulation sleeving from ground wire B
and unsolder pin B.
Keep pin B.
TM 3-1040-268-20&P
2-29