TM 5--2350--378--24&P
0032 00--4
REPAIR HDC FORWARD RIGHT MANIFOLD ASSEMBLY -- Continued
0032 00
ASSEMBLY
CAUTION
S
Assembly should be performed in a clean environment and protective dust covers
or caps should be installed on all openings to prevent contamination. Dirt can
damage parts and cause malfunctions.
S
When securing forward right manifold in vice, exercise extreme care not to mar any
surfaces or damage components
S
Do not over torque.
1.
Install new o--ring (Figure 3, item 2), transducer T11 (Figure 3, item 1), two o--rings (Figure 3, item 15), two
new telfon backups (Figure 3, item 16), two new o--rings (Figure 3, item 17), two new telfon backups
(Figure 3, item 16), and two two--way (NO) valves V2 and V10 (Figure 3, item 14) into right forward manifold
(Figure 3, item 9).
2.
Install two o--rings (Figure 3, item 5), two adapters (Figure 3, item 6), o--ring (Figure 3, item 8), adapter
(Figure 3, item 7), o--ring (Figure 3, item 12), adapter (Figure 3, item 13), two new o--rings (Figure 3,
item 10), two adapters (Figure 3, item 11), two new o--rings (Figure 3, item 3), and two adapters (Figure 3,
item 4) into right forward manifold (Figure 3, item 9).
Figure 3. Assembly of HDC Forward Right Manifold
END OF TASK