TM-5-5420-202-20-3

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 3 OF 4

OCTOBER 1985

  TM-5-5420-202-20-3 - Page 474 of 1060

TM 5-5420-202-20-3
ELECTRICAL WIRING HARNESS CABLE CONNECTOR REPAIR (Sheet 6 of 18)
Terminal Connector Repair (Sheet 1 of 2)
TOOLS:
Electrical connector repair tool kit
Diagonal cutting pliers
Heat gun
Pocket knife
SUPPLIES:
Heat-shrink tubing (Item 60, Appendix D)
Terminal
PRELIMINARY PROCEDURES:
Disconnect three battery ground straps (page 10-268)
Loosen or remove cable clamps as required
1.
Using knife, slit heat-shrink tubing (A)
along its entire length. Throw heat-shrink
tubing (A) away.
3.
Using hand wire stripper, strip insulation
from cable (C) equal to well depth in
terminal (B).
Go on to Sheet 2
2.
Using diagonal cutting pliers, cut terminal
(B) from cable (C). Throw terminal (B)
away.
Change 4
10-303