TM-5-5420-202-20-3

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 3 OF 4

OCTOBER 1985

  TM-5-5420-202-20-3 - Page 483 of 1060

TM 5-5420-202-20-3
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR (Sheet 15 of 18)
Female Connector With Sleeve (14 and 16 Gauge Cable) Repair (Sheet 1 of 1)
TOOLS:
Electrical connector repair tool kit
Diagonal cutting pliers
SUPPLIES:
Silicone compound
PRELIMINARY PROCEDURES:
(Item 32, Appendix D)
Disconnect three battery ground straps (page 10-268)
Loosen or remove cable clamps as required
1.
Slide shell (A) and sleeve (B)
back along cable (C).
2. Using diagonal cutting pliers, cut
terminal (D) from cable (C).
Throw teriminal (D) away.
3.
4.
Using hand wire stripper, strip
insulation from cable (C) equal
to well depth in terminal (D).
Insert stripped cable end (E)
into well in terminal (D).
7.
Slide shell (A) forward along cable (C) until tight against sleeve (B).
8. Using multimeter, check continuity of repair circuit.
9. Tighten or install cable clamps as required.
10. Connect three battery ground straps (page 10-268).
End of Task
10-312
5.
Using crimping tool, crimp terminal (D).
6.
Slide sleeve (B) forward along cable (C)
until tight against terminal (D).
TA249253


Back to Top