TM 5-5420-202-20-3
FUEL TANK CAPACITOR AND HOUSING ASSEMBLY REPLACEMENT (RIGHT)
(Sheet 1 of 5)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
10-316
Cleaning and Inspection
10-318
Installation
10-318
TOOLS:
Flat-tip screwdriver
1/2 in. socket with 1/2 in. drive
Diagonal cutting pliers
Ratchet with 1/2 in. drive
Slip-joint pliers
Torque wrench with 1/2 in. drive (0-175 lb-ft)
Putty knife
SUPPLIES:
Lockwire (Item 61, Appendix D)
Lint-free cloth (Item 12, Appendix D)
Gaskets
Dry cleaning solvent (Item 55,
Gloves (Item 69, Appendix D)
Appendix D)
Goggles (Item 70, Appendix D)
REFERENCE:
TM 5-5420-202-10
PRELIMINARY PROCEDURES:
Remove powerplant (page 5-2)
Drain right fuel tank (TM 5-5420-202-10)
Remove floor access cover (page 17-5)
REMOVAL:
1.
Using cutting pliers, remove lockwire (A)
from fuel pump cover (B).
2.
Using socket, remove 12 screws and washers
(C) securing cover (B).
Go on to Sheet 2
TA249257
10-316