2–13.
TOP PANEL MAINTENANCE INSTRUCTIONS CONTINUED
a.
REMOVAL CONTINUED
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged.
Handle with care when
removing or replacing it.
Failure to
comply may result in damage to
equipment.
3.
Inspect EMI shielding gasket (4) in groove of
housing (5) for cuts, nicks, or signs of
stretching.
Discard EMI shielding gasket if
unserviceable.
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged.
Handle with care when
removing or replacing it.
Failure to
comply may result in damage to
equipment.
2.
If removed, install EMI shielding gasket (4) in
groove in housing (5).
5
4