TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 51 of 266

TM 9–1200–215–34&P
2–16
2–15.
1553 CCA MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
#1 Crosstip Screwdriver Socket Wrench (item 21,
Appendix E)
Materials/Parts:
Bag, Plastic (item 6, Appendix D)
Box, Shipping (item 10, Appendix D)
Equipment Conditions:
Stabilizer bracket removed; if not, remove stabilizer
brackets in accordance with paragraph 2–14
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
NOTE
Tag wires before removing.
2.
Disconnect two channel connectors (1) from
J1 and J2 connectors located on end of 1553
CCA (2).
3.
Remove screw (3) and flat washer (4) from
holddown of 1553 CCA (2).
4.
Gently remove 1553 CCA (2) from backplane
connector J8 (5) in ACU housing.
1
2
3
4
5


Back to Top