TM 9–1200–215–34&P
2–21
2–17.
TCIM CCA MAINTENANCE INSTRUCTIONS CONTINUED
a.
REMOVAL CONTINUED
CAUTION
The connector panel assembly is
attached by cables to internal
components of ACU and cannot be
moved very far from housing without
putting strain on those cables.
Exercise caution when removing
bottom cover from ACU housing.
Failure to comply may result in
damage to equipment.
5.
Remove ACU connector panel (6) by removing
16 screws (7) and 16 flat washers (8).
Lift
connector panel off housing.
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged.
Handle with care when
removing or replacing it.
Failure to
comply may result in damage to
equipment.
6.
Inspect EMI shielding gasket (9) in groove in
housing (10) for cuts, nicks, or signs of
stretching.
Discard EMI shielding gasket if
unserviceable.
7.
Loosen two captive screws (11) securing card
edge connector (12) to side of TCIM CCA.
8.
Gently remove TCIM CCA (2) from backplane
connector J5 (13) in ACU housing and place
CCA in ESD protective bag.
6
7
8
9
2
11
12
13
10