TM 9–1200–215–34&P
2–15
2–14.
CCA STABILIZER BRACKET MAINTENANCE INSTRUCTIONS CONTINUED
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
NOTE
The two stabilizer brackets are
different lengths.
The longer
bracket should be positioned at
middle of ACU.
2.
Place CCA stabilizer bracket (1 and 2) into
position in ACU and align holes.
3.
Insert four screws (3), four new lockwashers
(4), and four flat washers (5) securing each
stabilizer bracket into ACU.
Torque screws to
20 in.–lb (2.3 N
S
m).
4.
Install top panel in accordance with procedure
outlined in paragraph 2–13.
1
5
4
3
2
5
4
3