TM 9–1200–215–34&P
2–14
2–14.
CCA STABILIZER BRACKET MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–75 in.–lb (item 40, Appendix E)
Socket Wrench, Sockethead Screw, 9/64” (item 67,
Appendix E)
Materials/Parts:
Lockwasher (item 1, Appendix F)
Equipment Conditions:
Top panel removed; if not, remove top panel in ac-
cordance with procedure in paragraph 2–13
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
2.
Remove CCA stabilizer brackets (1 and 2) by
removing four screws (3), four lockwashers
(4), and four flat washers (5) securing each
stabilizer bracket.
Lift stabilizer bracket from
ACU.
Discard lockwashers.
1
5
4
3
2
5
4
3