TM 9–1200–215–34&P
2–28
2–18.
CPU CCA MAINTENANCE INSTRUCTIONS CONTINUED
b.
INSTALLATION
CONTINUED
9.
Insert screw (18) and flat washer (19) into
holddown of CPU CCA.
Torque screw to 5
in.–lb (0.6 N
S
m).
10. Install two insulating blocks (1) by inserting
three screws (2), three new lockwashers (3),
and three flat washers (4). Torque screws to
15 in.–lb (1.7 N
S
m).
11.
Connect Ethernet cable connector (12) to CPU
CCA edge.
12. Connect VGA cable connector (15) to CPU
CCA edge.
Tighten two captive screws (14).
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged.
Handle with care when
removing or replacing it.
Failure to
comply may result in damage to
equipment.
13. If removed, install EMI shielding gasket (11) in
groove in housing (10).
14.
Position connector panel (7) on housing and
align holes.
15. Install 16 screws (8) and 16 flat washers (9).
Following torque sequence chart below, torque
screws to 30 in.–lb (3.4 N
S
m).
10
16
31
1
5
8
12
4
15
9
13
1
7
14
2
6
16. Install stabilizer brackets in accordance with
procedure outlined in paragraph 2–14.
1
1
2
3
4
4
3
2
7
8
9
18
19
15
14
12
11
10