TM 9–1200–215–34&P
2–33
2–20.
LED
MAINTENANCE INSTRUCTIONS CONTINUED
a.
REMOVAL CONTINUED
CAUTION
The connector panel assembly is
attached by cables to internal
components of ACU and cannot be
moved very far from housing without
putting strain on those cables.
Exercise caution when removing
bottom cover from ACU housing.
Failure to comply may result in
damage to equipment.
2.
Remove ACU connector panel assembly (1) by
removing 16 screws (2) and 16 flat washers
(3).
Lift connector panel off housing.
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged.
Handle with care when
removing or replacing it.
Failure to
comply may result in damage to
equipment.
3.
Inspect EMI shielding gasket (4) in groove in
housing (5) for cuts, nicks, or signs of
stretching.
Discard EMI shielding gasket if
unserviceable.
NOTE
Tag both leads before cutting.
4.
Cut leads (6) from back of LED (7).
5.
Remove nut (8) and star washer (9).
6.
Pull body of LED (7) with gasket (10) from the
front of the housing (5).
7.
Remove and discard insulation sleeving (11)
from leads (6).