2–20.
LED
MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Minigun, Hot Air (item 15, Appendix E)
Torque Wrench, 0–75 in.–lb (item 40, Appendix E)
Materials/Parts:
Insulation Sleeving (item 26, Appendix D)
Solder (item 28, Appendix D)
Soldering Flux (item 18, Appendix D)
Alcohol (item 4, Appendix D)
Brush, Acid Swabbing (item 11, Appendix D)
Equipment Conditions:
Top panel removed; if not, remove top panel in
accordance with paragraph 2–13
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
NOTE
The ACU contains two LEDs, Power
and Bit.
Both LEDs are removed
and installed in the same manner.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.


Back to Top